Home

Filter Bag

M1 Lab Side Filters

Highlights:

M1 Lab Side Filters are intended for Pre Storage Leukodepletion.

Primes directly with red cell conveniently, no saline is required.

Attached Transfer Bag, Single Wafer is required.

M1 Lab side Filters are soft filters with no plastic covering, and can be pressed softly for smooth filtration.

Ensures Log 4 i.e. 99.99% Leukodepletion.

quintuple TAB Inline Filter

Highlights:

Single Step Sterilization of the Complete System (bags and Filter).

Priming by Gravity ,No Squeezing of Blood Bag required.

Funnel Shape design of Filter prevent loss of even single drop of filtered Blood , ensure Red Cell recovery.

Can be used with any existing Automated Component Expresser.

Ease of use during processing. Ensures Log 4 i.e. 99.99% Leukodepletion.

Quadruple TAT inline Filter

Highlights:

Innovative Triple Blood Bag System with M1 Inline Filter to ensure 99.99% Leukodepletion.

M1 TIB can be used to get Log 4 Leukodepleted Blood Products by Manual Method of Component Separation.

Funnel Shape design of Filter prevent loss of even single drop of filtered Blood , ensure Red Cell recovery.

100% Closed System.

No Automated equipment is required.

LABSIDE & BEDSIDE FILTERS

TYPE OF BLOOD BAGQTY in mlCODEDESCRIPTIONUNITS / CARTON
Labside filter for WB (Whole blood) with empty transfer bag.500 mlMWBLS50Mitra WB (Whole blood ) filter with 500 ml empty transfer bag for labside leukodepletion filter.60
Labside filter for RBC (Red blood cells) with empty transfer bag.500 mlMRCLS50Mitra RBC (Red blood cells ) filter with 500 ml empty transfer bag for labside leukodepletion filter.60
Labside filter for PL (Platelets) with empty transfer bag.500 mlMPLLS50Mitra PL (Platelets ) filter with 500 ml empty transfer bag for labside leukodepletion filter.60
Bed side filter for RBC (Red Blood cells) with 60 mm Drip Chamber.NAM1RBCBSSterile filter assembly system for bedside leukodepletion (for RBC)60
Bed side filter for PL (Platelets) Drip ChamberNAM1PLTBSSterile filter assembly system for bedside leukodepletion (for platelets)60
TAB INLINE FILTERS
Quadruple blood bag with inline leukodepletion filter of RBC and platelet With PDS and NPD.350 mlQu35MRPSI-IIBlood bag Quadruple 350 ml -CPD IP/SAG-M with inline leukodepletion filter of RBC and platelet filter With PDS and NPD, Top and Bottom (TAB).20
Quintiple blood bag with inline leukodepletion filter of RBC With PDS and NPD. ( TOP & BOTTOM)350 mlOt35MRSI-IIBlood bag Quintiple 350 ml -CPD IP/SAG-M with inline leukodepletion filter RBC With PDS and NPD, Top and Bottom (TAB).20
Quadruple blood bag with inline leukodepletion filter of RBC and platelet With PDS and NPD.450 mlQu45MRPS-IIBlood bag Quadruple 450 ml -CPD IP/SAG-M with inline leukodepletion filter of RBC and platelet filter With PDS and NPD, Top and Bottom (TAB).20
Quintiple blood bag with inline leukodepletion filter of RBC With PDS and NPD.450 mlOt45MRSI-IIBlood bag Quintiple 450 ml -CPD IP/SAG-M with inline leukodepletion filter RBC With PDS and NPD, Top and Bottom (TAB).20
TIB INLINE FILTERS
Quadruple blood bag with inline leukodepletion filter for RBC (TIB).(Top and Top)350 mlQu35MRSI-IIBlood bag Quadruple 350 ml -CPD IP/SAG-M with inline leukodepletion filter with PDS and NPD. (Top and Top).20
Quadruple blood bag with inline leukodepletion filter for RBC (TIB).(Top and Top)450 mlT45MRSI-IIBlood bag Quadruple 450 ml -CPD IP/SAG-M with inline leukodepletion filter with PDS and NPD. (Top and Top).20
Quadruple blood bag with inline leukodepletion filter for WB (Whole blood) Top & Top.350 mlQu35MWBSI-IIBlood bag Quadruple 350 ml -CPD IP/SAG-M with inline leukodepletion filter for WB (whole blood) with PDS and NPD. (Top and Top).20
Quadruple blood bag with inline leukodepletion filter for WB (Whole blood) Top & Top.450 mlQu35MWBSI-IIBlood bag Quadruple 450 ml -CPD IP/SAG-M with inline leukodepletion filter for WB (whole blood) with PDS and NPD. (Top and Top).20
Quadruple blood bag with inline leukodepletion filter of RBC and platelet With PDS and NPD.350 mlQu35MRPSI-IIBlood bag Quadruple 350 ml -CPD IP/SAG-M with inline leukodepletion filter of RBC and platelet filter With PDS and NPD, Top and Bottom (TAB).20